RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8, 9 cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction.
The most popular design is of PTFE Insulation & outer jacket of PTFE, GLASS FIBER & SILICONE RUBBER as per requirement. Metal over braid of SS & SPC, if required
ELTEC PTFE Insulated RTD Extension wires conforms to US Military MIL – W – 16878 and Indian defense specifications JSS 51034. As per these standards, these wires are classified in three main working voltage grades.
APPLICATIONS |
· RTD Sensors & Extension Wires |
· RTD Autoclave |
· Medical Instruments & Scientific Equipments |
· Sensors, Load Cells & Pressure Transducers |
· Electronics & Communication Equipment |
· Process Instrumentation |
Product Details:
Minimum Order Quantity | 100 Meter |
Conductor Type | Silver Plated Copper / Nickel Plated Copper |
Size | 24*7*32 / 26*7*34 / 20*19*32 / 22*19*34 as per client's requirements |
Material | PTFE / FEP / PFA / PVC |
Product Type | RTD CABLES |
Brand | ELTEC |
Thermocouple Type | RTD |
Number Of Core | As per client's requirements |
Usage/Application | Use to transmit signals from RTD SENSORS to control unit |
Operating Temp | -60 to 260 C |
Power/Voltage | 250V / 600V / 1000V |
RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2 wire, 3 wire configuration..
ELTEC PTFE Insulated RTD Extension wires conforms to US Military MIL – W – 16878 and Indian defense specifications JSS 51034. As per these standards, these wires are classified in three main working voltage grades.
CONSTRUCTIONAL DETAILS:
Conductor | Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL – W - 16878 & JSS 51034, Refer Table for most popular & standard wire sizes |
Core Insulation | Fused PTFE Tape , FEP, PFA Fiber Glass, Silicone Rubber Extruded, Refer Ordering Code |
Construction | Parallel / Twisted Conductors |
No. of Triad | 1, 2 or more |
Outer Sheath | Fused PTFE Tape , FEP, PFA, Fiber Glass Insulated, Silicone Rubber Extruded, Refer Ordering Code |
SS JACKET | Silver Plated Copper wire Braid or SS Over Metal Braid |
Color Coding | Confirms to EN 60751 |
Additional Information:
Product Details:
Minimum Order Quantity | 100 Meter |
Size | 28 AWG to 20 AWG |
Usage/Application | RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. |
Insulating Material | PTFE |
Brand | ELTEC |
Number Of Cores | 2,3,4,6 or more |
Conductor Material | Silver Plated Copper / Nickle Plated Copper wires |
Country of Origin | Made in India |
ELTEC PTFE Insulated RTD Extension wires conforms to US Military MIL – W – 16878 and Indian defense specifications JSS 51034.
Additional Information:
Product Details:
Country of Origin | Made in India |
Conductor | Silver Plated / Nickel Plated Copper wires |
Conductor size | 28 AWG to 20 AWG Multi stranded conductors |
Insulation | Silicone Rubber or PTFE as per user requirement |
Sheath Material | Silicone Rubber |
Color Code Specification | As per EN 60751 |
RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8, 9 cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction.
Silicone Rubber have fine electrical properties, good chemical stability, flame retardant, low smoke emission and excellent resistance to heat and cold. Silicone rubber has exceptional weather resistance. Ozone created by corona discharge does not deteriorate silicone rubber. Thus, silicone rubber can be exposed to wind, rain and UV rays for longer periods without any change in its physical propertiesAdditional Information:
Product Details:
Minimum Order Quantity | 100 Meter |
Is It Insulated | Insulated |
Cable Size | 28 AWG TO 18 AWG Multi Stranded |
Insulation Material | PTFE (Teflon) |
Voltage | 250 V / 600 V / 1000 V |
Insulation | PTFE / FEP / PFA |
Type Of Cable | RTD SHIELDED CABLE, PTFE INSULATED & SHEATHED |
Usage/Application | Manufacturing of RTD SENSORS & its Extension Wires |
Part Number | Rx TTST |
Temperature Range | -50 to 250 deg C |
Flame Retardant | Yes |
Brand | ELTEC |
Product Type | Shielded RTD CABLE, Shield of SS Metal Braid / Nickel Plated or Silver Plated Copper wire braid |
Length | 100 Mtrs. / 200 Mtrs. / 500 Mtrs. |
Cable Conductor | Silver Plated Copper Wire / Nickel Plated Copper Wire |
Country of Origin | Made in India |
Shielding Type | Shielded |
No. of Core | 2 / 3 / 4 / 6 / 8 or even more |
Shield | SS Metal Braid / SPC Metal Braid / NPC Metal Braid |
Sheath | PTFE / FEP / PFA |
APPLICATIONS |
· Manufacturing of RTD Sensors |
· Furnaces & Ovens |
· Plastic Processing Equipments |
· Aerospace & Cryogenics |
· Sensor Circuits |
· Various Processing Industries |
PRODUCT FEATURES |
· Continuous use up to 260 °C |
· Single exposure up to 350 °C |
· Good Thermal Durability & Strength |
· Flame Retardant |
· Superior Abrasion Resistance |
· Better flexibility |
Additional Information:
Product Details:
Temperature Range | -50 to 250 deg C |
Insulation | PTFE / FEP / PFA |
Type | PT100 |
Conductor | Silver Plated Copper Wire / Nickel Plated Copper Wire |
No. of Core | 2 / 3 / 4 / 6 or even more |
Sheath | PTFE / FEP / PFA |
Conductor Size | 28 AWG to 20 AWG |
Outer Shield | SS Metal Over Braid / Silver Plated or Nickel Plated Copper Wire |
Application: | Manufacturing of RTD SENSORS or Extension Wire for RTD sensors |
RTD wire is commonly used to link the RTD SENSOR to control instrumentation. It may also be used to build the sensing point with RTD SENSOR or can used to connect to DATA LOGGERS. It is also used to carry transmitter output of 4 to 20mA to control instrumentation.
SS Metal Over Braid shield cuts the noise disturbances & provides mechanical protection to the cable.