We offer a wide range of TEMPERATURE TRANSMITTER
Product Details:
| Minimum Order Quantity | 1 Piece |
| Sensor Type | RTD |
| Operating Range | 0 to 50 C |
| Output Type | 4 to 20 mA |
| Model Name/Number | TMT 131 |
| Brand | I TRANS |
| Supply Voltage Limits | 7.5 VDC to 45 V DC |
| Country of Origin | Made in India |
| Input Type | RTD PT 100 and all type of TC J, K, N, T, E, R, S, B |
| Configuration | USB cable for programming from PC along with software |
| Usage/Application | Converts all Thermocouple, RTD, mV, Ohms signals into scalable 4 to 20 mA analogue output sig |
| Accuracy | 0.1% for RTD & 0.2% for all type of Thermocouple |
| DIN RAIL Temperature transmitter TMT130 |
Product Details:
| Minimum Order Quantity | 1 Nos |
| Application | Converts TC, RTD, mV, Ohms input into line scalable 4 to 20mA |
| Model Name/Number | TMT 131 |
| Brand | ITHERM |
| Accuracy | 0.1% for RTD & 0.2% for all type of Thermocouple |
| Rated Supply Voltage | 24 VDC |
| Response Time | 0.3 microA |
| Output Type | 4 to 20 mA |
| Country of Origin | Made in India |
| Input | RTD PT 100, All Type of TC J,K,T,E,N,R,S,B |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Input Type | RTD + TC |
| Sensor Type | RTD |
| Output Signal | 4–20 mA |
| Mounting Type | Head Mount |
| Output Value | 4 to 20mA |
| Application | Use for converting RTD Signal into scalable analog Input signal 4 to 20mA |
| Usage/Application | Converts RTD and all type of TC input into scalable 4 to 20mA |
| Input Value | RTD PT 100 |
| Mounting | Head Mount |
| Programming | Can be programmed with user freindly software & USB |
PC Programmable Head Mount Temperture Transmitter which takes input from RTD and convert it into a scalable analogue signal of 4 to 20mA.
PERFORMANCE
· 2-wire technology, 4 to 20mA analogue output
· High accuracy in total ambient temperature range
· Internal cold junction compensation
· Wide voltage supply range
· Customer specific measurement range setting or expanded SETUP
· Simple and user friendly software
· USB communication
INPUT
Type : RTD PT 100
Measurement ranges : -200 to 850°C
Connection type : 3-wire connection
OUTPUT
Output signal : 2 Wire, 4 to 20mA scalable analogue signal output
Current Alarm Output : 3.6mA or 22mA when Sensor Damage or Break
TECHINCAL SPECIFICATIONS
Damp : 0-32s
Current Limit : ≤ 22mA
Saturation Current : Low 3.8mA ; High 20.6mA
Response Time : ≤ 0.8s
Data Refresh Rate : 4 times/sec
Accuracy : ± 0.1%
Stability : 0.01 ??C
Power Supply : 10 to 32 VDC
Product Details:
| Minimum Order Quantity | 5 Piece |
| Output Signal | 4~20 mA |
| Accuracy | 0.2 % |
| Input Types | Temperature |
| Application | Use to convert all type of RTD 7 Thermocuple signals into scalable linear 4 to 20mA |
| Model Number | TR 213 |
| Output Value | 2 Wire, 4 to 20mA |
| Usage/Application | Converts RTD & Thermocouple Input into linear scalable 4 to 20mA. |
| Input Value | Universal All type of RTD & Thermocouple Input |
| Power | 24 VDC |
| Rated Supply Voltage | 24 VDC |
| Supply Voltage Limits | 24 VDC |
TT 210 is a Head Mount Non isolated universal temperature transmitter for resistance thermometers (RTD), thermocouples (TC), resistance & voltage (mV) which converts all these data signals into scalable 4 to 20mA analogue output signal.
This is a user programmable temperature transmitter which can be programmed for input signal from ANDROID SMART PHONE or LAPTOP via data cable & user friendly operating software.
Performance Features:
Technical Data
| Input | RTD, TC, OHM, mV |
| Output | 4 to 20 mA |
| Supply voltage | 7.5 to 45 VDC |
| Cold junction | Internal |
| Influence of ambient | Negligible |
| Load influence | Negligible |
| Power supply influence | Negligible |
| Resolution | 0.3 uA |
| Installation | Sensor head from B |
| Operation | PC - programmable |
| Weight | Approx. 35 GMS |
| Dimensions | 44 MM × 22. 5 MM (Φ × H) |
Pl. click on the pdf file to download data sheet.