Product Details:
Conductor Type | Thermocouple Original, Extension & Compensating Grade |
Model Name/Number | K FFS |
Size | 12 AWG to 24 AWG in solid & multi strand |
Product Type | Fiber Glass & Outer SS Metal Shielded Thermocouple Wires |
Material | FIBER GLASS |
Usage/Application | Industrial |
Brand | ELTEC |
Thermocouple Type | K-Type |
Length | 100 Mtrs. / 500 Mtrs. / 1000 Mtrs. |
Accuracy | As per ASTEM E 230 & ANSI MC 96.1 & IEC 60584-2 |
Number Of Core | 2,4,6 or more |
Limit Of Error | Class 1 IEC 60584-2 & As per ASTEM E 230 & ANSI MC 96.1 & |
Operating Temp | 0 to 450 C |
Outer Jacket | FIBER GLASS BRAIDED with high temp. Impregnation |
Outer Braiding | SS Metal Braided |
K Type Thermocouple wire is used to build the sensing point and can be used as a K TYPE THERMOCOUPLE SENSOR or used in manufacturing of THERMOCOUPLE ASSEMBLIES .
Thermocouple Extesnion / Compensating Grade wires are used to connect the K Type Sensor to Control Instrumentation.
Fiber glass insulation is ideal for general application requiring moderate abrasion, moisture resistance & high temperature resistance.
Additional Information:
Product Details:
Conductor Type | Thermocouple Original, Extension & Compensating Grade |
Size | 12 AWG to 24 AWG in solid & multi strand |
Material | FIBER GLASS |
Brand | ELTEC |
Thermocouple Type | J-Type |
Insulation | FIBER GLASS |
Conductor Material | +ve Iron,-ve Constantan |
Outer Shield | Fine SS Metal braid |
Thermal Acuarcy | As per ANSI MC 96.1 & IEC 60584 |
J Type Thermocouple wire is used to build the sensing point and can be used as a J TYPE THERMOCOUPLE SENSOR or used in manufacturing of THERMOCOUPLE ASSEMBLIES .
Thermocouple Extesnion / Compensating Grade wires are used to connect the J Type Sensor to Control Instrumentation.
Fiber glass insulation is ideal for general application requiring moderate abrasion, moisture resistance & high temperature resistance.
Additional Information:
Product Details:
Minimum Order Quantity | 100 Meter |
Conductor Type | N TYPE |
Product Type | N TYPE FIBER GLASS INSULATED WIRE |
Material | Nisil, Nicrosil |
Usage/Application | Industrial |
Brand | ELTEC |
Thermocouple Type | N Type |
Type of Thermocouple Wire | N |
Conductor | Thermocouple Original & Extension Grade |
Insulation | FIBER GLASS |
Size of Conductor | 7*36 SWG - 0.23 sq.mm |
Type N thermocouple grade wire is commonly used to build the thermocouple probe. It may also be used to build the sensing point and can be used as a n type thermocouple sensor or used in manufacturing thermocouple assemblies or can used to connect to the data loggers via thermocoupole connectors.
Fiberglass insulation is ideal for general application requiring moderate abrasion, moisture resistance and high temperature resistance.
conductor | solid or multi-stranded original thermocouple grade |
core insulation | fiberglass varnished |
core laying | parallel or twisted |
no. Pair of | 1, 2 or more |
outer sheath | fiberglass varnished |
braiding | fine annealed soft mirror finished ss wire, if reqd. |
color coding | as per iec, ansi, bs, din, nfc, jis etc. Refer table |
part no. | awg wire size | type of wire | insulation | max. Temp. | overall dimensions | |
---|---|---|---|---|---|---|
core | overalls | |||||
n type wire with the individual scores & overall fiberglass insulation | ||||||
nx 16ff | 16 | solid | fiberglass braid | fiberglass braid | 400 ° c | |
nx 18ff | 18 | solid | 400 ° c | |||
nx 20ff | 20 | solid | 400 ° c | |||
nx 22ff | 22 | solid | 400 ° c | |||
nx 24ff | 24 | solid | 400 ° c | |||
nx 26ff | 26 | solid | 400 ° c | |||
nx 28ff | 28 | solid | 400 ° c | |||
nx * 19 32ff | 32 | 19x32 | 400 ° c | |||
nx 7 * 32 ff | 32 | 7 x 32 | 400 ° c |
Additional Information:
Product Details:
Minimum Order Quantity | 100 Meter |
Conductor Type | Extension / Compensating |
Size | 12 AWG to 24 AWG in solid & multi strand |
Material | FIBER GLASS |
Brand | ELTEC |
Thermocouple Type | S Type |
Length | 100 Mtrs. / 500 Mtrs. / 1000 Mtrs. |
Country of Origin | Made in India |
R / S TYPE THERMOCOUPLE EXTNENSION FIBER GLASS WIRES are generally used to wire is commonly used to link the thermocouple to control instrumentation or can used to connect to data loggers via thermocouple connectors.
Fiber glass insulation is ideal for general application requiring moderate abrasion, moisture resistance & high temperature resistance.Additional Information:
Product Details:
Minimum Order Quantity | 100 Meter |
Brand | ELTEC |
Number Of Core | 2,4,6 or more |
Usage/Application | Use to manufacture thermocouple sensor & also as an extension wire from thermocouple to control unit |
Referred Standards | As per ASTEM E 230 & ANSI MC 96.1, IEC 60584 - 3, BS , DIN, JIS |
Conductor Type | Thermocouple Original & Extension Grade |
Thermocouple Type | E TYPE |
Accuracy | As per ASTEM E 230 & ANSI MC 96.1 & IEC 60584-2 |
Operating Temp | 0 to 450 C |
Range | 0 to 900 |
Limit Of Error | +-1.1 or 0.4% whichever is greater |
Temperature | 0 to 900 C |
Outer Jacket | FIBER GLASS BRAIDED with high temp. Impregnation |
Size | 12 AWG to 24 AWG in solid & multi strand |
Country of Origin | Made in India |
TYPE OF TC |
Metal Alloy + ve leg |
Metal Alloy – ve leg |
Et / Ex |
Ni Cr - Chromel |
Cu Ni - Constantan |
APPLICATIONS |
· Manufacturing of Temperature Sensors |
· Furnaces & Ovens |
· Plastic Processing Equipments |
· Heat Treatment |
· Thermocouple Circuits |
· Various Processing Industries |
|
PRODUCT FEATURES |
· Continuous use up to 500 °C |
· Single exposure up to 650 °C |
· Good Thermal Durability & Strength |
· Flame Retardant |
· Superior Abrasion Resistance |
· Better flexibility |
Additional Information:
Product Details:
Brand | ELTEC |
Accuracy | As per ASTEM E 230 & ANSI MC 96.1 & IEC 60584-2 |
Outer Braiding | SS Metal Braided |
Size | 12 AWG to 24 AWG in solid & multi strand |
Thermocouple Type | T-Type |
Model Name/Number | Tt FFS |
Limit Of Error | +-1.0 (1.8) or +-0.75% +-1.0 (1.8) or +-1.5% |
Outer Jacket | FIBER GLASS BRAIDED with high temp. Impregnation |
Number Of Core | 1 Pair, 2 Pair or even more as per customer requirement |
Usage/Application | Use to manufacture thermocouple sensor & also as an extension wire from thermocouple to control unit |
Operating Temp | 0 to 350 C |
Country of Origin | Made in India |
Temperature | 0 to 350 C |
Additional Information:
Product Details:
Minimum Order Quantity | 100 Meter |
Conductor Type | Thermocouple Original, Extension & Compensating Grade |
Size | 12 AWG to 24 AWG in solid & multi strand |
Material | PTFE |
Color | As per ANSI MC 96.1, IEC 60584-3 and other International color code on request |
Brand | ELTEC |
Thermocouple Type | K-Type |
Temperature | -60 C to 260 C |
Length | 100 Mtrs. / 500 Mtrs. / 1000 Mtrs. |
Accuracy | As per ASTEM E 230 & ANSI MC 96.1 & IEC 60584-2 |
Number Of Core | 2,4,6 or more |
Usage/Application | Use to manufacture thermocouple sensor & also as an extension wire from thermocouple to control unit |
Range | 0 to 1250 C |
Model Name/Number | Kt TT |
Limit Of Error | Class 1 IEC 60584-2 & As per ASTEM E 230 & ANSI MC 96.1 & |
Operating Temp | -60 to 260 C |
Outer Jacket | PTFE |
Referred Standards | As per ASTEM E 230 & ANSI MC 96.1, IEC 60584 - 3, BS , DIN, JIS |
Outer Braiding | SS Metal Braided |
Country of Origin | Made in India |
K TYPE thermocouple wire is commonly used to link the thermocouple to control instrumentation. It may also be used to can used to connect to data loggers via thermocouple connectors.
TYPE OF TC |
Metal Alloy + ve leg |
Metal Alloy – ve leg |
Measuring Temp. Range |
Thermal Accuracy as per ASTM E 230 & ANSI MC 96.1 |
Kt - Thermocouple Grade |
Chromel |
Alumel |
0 °C - 1250 °C |
± 1.5 ºC or ± 0.4 % whichever is greater |
Additional Information:
Product Details:
Minimum Order Quantity | 100 Meter |
Conductor Type | Solid & Multi stranded |
Size | 12 AWG to 24 AWG |
Material | PTFE |
Color | Black |
Brand | ELTEC |
Thermocouple Type | J-Type |
Temperature | -60 C to 260 C |
Length | 100 Mtrs. / 500 Mtrs. / 1000 Mtrs. |
Country of Origin | Made in India |
J TYPE thermocouple wire is commonly used to link the thermocouple to control instrumentation. It may also be used to build the sensing point and can be used as a J TYPE THERMOCOUPLE SENSOR or used in manufacturing of THERMOCOUPLE ASSEMBLIES or can used to connect to data loggers via thermocouple connectors.
TYPE OF TC |
Metal Alloy + ve leg |
Metal Alloy – ve leg |
Measuring Temp. Range |
Thermal Tolerance as per ASTM E 230 & ANSI MC 96.1 Special Grade & IEC 60584 -2 Class A |
|
||
J |
Iron, FE |
Copper Nickel, Cu Ni |
0 °C - 750 °C |
± 1.5 or 0.4% whichever is greater |
|
Additional Information:
Product Details:
Conductor Type | Solid & Multistranded |
Size | 12 AWG to 24 AWG in solid & multi strand |
Material | PTFE |
Color | Blue |
Brand | ELTEC |
Thermocouple Type | T-Type |
Thremocouple Calibration | Type T Thermocouple Wire |
Conductor | +ve Copper,-ve Constantan |
Insulation | PTFE (Poly Tetra Fluro Ethylene) |
Operating Temperature Range | Upto 260 C |
Temperature Measuring Range | 0 to 350 C |
Thermal Accuracy | As per ASTM E230 / ANSI MC 96.1 and IEC 60584-2 |
T TYPE PTFE INSULATED THERMOCOUPLE WIRE
Type T thermocouple grade wire is commonly used to build the thermocouple probe. It may also be used to build the sensing point and can be used as a T type thermocouple sensor or used in manufacturing thermocouple assemblies or can used to connect to the data loggers via thermocoupole connectors.
TYPE OF TC |
+ ve leg |
– ve leg |
Measuring Temp. Range |
Thermal Tolerance as per ASTM E 230 & ANSI MC 96.1 & IEC 60584 - 2 |
T |
COPPER | CONSTANTAN | 0 TO 350 C | ± 0.5 or 0.4% whichever is greater |
|
Additional Information: