Product Details:
Minimum Order Quantity | 100 Meter |
Number Of Core | 1 Pair (2 Core) or more |
Accuracy | As per ASTM E 230 - MC 96.1 & IEC 60584 - 2 |
Brand | ELTEC |
Usage/Application | Manufacturing of thermocouple sensors or extension wires from thermocouple unit to control panel |
Referred Standards | ASTM E 230 ANSI MC 96.1 / IEC 60584-2 |
Type Of Thermocouple Calibration | J, K, T, E, N, R, S, B |
Country of Origin | Made in India |
Material | FIBER GLASS INSULATION |
Thermocouple Type | J, K, T, E, N, R, S, B |
Outer Jacket | FIBER GLASS BRAIDED with high temp. Impregnation |
Outer Braiding | SS Metal Braid Optional |
Temperature | 450 C |
Conductor Type | Thermocouple Original, Extension & Compensating Grade |
Size | 12 AWG to 24 AWG in solid and multi strand construction |
Length | 100 Mtrs. / 500 Mtrs. / 1000 Mtrs. / 2000 Mtrs. |
FIBER GLASS INSULATION is ideal for general application requiring moderate abrasion, moisture resistance & high temperature resistance. Designed for high temperature application in metal industries, forgings, aluminum, plastic processing equipments etc.
PRODUCT FEATURES |
· Continuous use up to 500 °C |
· Single exposure up to 650 °C |
· Good Thermal Durability & Strength |
· Flame Retardant |
· Superior Abrasion Resistance |
· Better flexibility |
APPLICATIONS |
· Manufacturing of Temperature Sensors |
· Furnaces & Ovens |
· Plastic Processing Equipments |
· Heat Treatment |
· Thermocouple Circuits |
· Various Processing Industries |
Additional Information:
Product Details:
Conductor Type | Thermocouple Original, Extension & Compensating Grade |
Size | 12 AWG to 24 AWG in solid & multi strand |
Brand | ELTEC |
Thermocouple Type | J, K, T, E, N, R, S, B |
Temperature | -60 C to 260 C |
Accuracy | As per ASTEM E 230 & ANSI MC 96.1 & IEC 60584-2 |
Number Of Core | 2,4,6 or more |
Usage/Application | Use to manufacture thermocouple sensor & also as an extension wire from thermocouple to control unit |
Limit Of Error | Class 1 IEC 60584-2 & As per ASTEM E 230 & ANSI MC 96.1 & |
Operating Temp | -60 to 260 C |
Outer Jacket | PTFE |
Referred Standards | As per ASTEM E 230 & ANSI MC 96.1 |
Country of Origin | Made in India |
PRODUCT FEATURES |
· Continuous use up to 260 °C |
· Single exposure up to 400 °C |
· Inert to most chemical & fluids |
· Unaffected by lubricants |
· Flame Retardant |
· Shielded construction provides noise reduction |
· Resistant to gamma radiation |
APPLICATIONS |
· Aerospace & Cryogenic |
· Chemical & Petroleum Plants |
· Laboratories |
· Field Heat Treating |
· Packaging |
C |
Additional Information:
Product Details:
Minimum Order Quantity | 300 Meter |
Size | 12 AWG to 24 AWG in solid & multi strand |
Thermocouple Type | J, K, T, E, N, R, S, B |
Application | Manufacturing of Thermocouple Sensors or used as an Extension wire from thermocouple to control unit |
Product Type | Silicone Rubber Insulated Thermocouple Cables |
Number Of Core | 2 Core / 4 Core or even more |
Accuracy | As per ANSI MC 96.1 & IEC 60584 |
Operating Temp | Upto 200 C |
Outer Jacket | Silicone Cable |
Referred Standards | ASTM E 230 & ANSI MC 96.1 |
Brand | ELTEC |
Type Of Thermocouple Calibration | J / K / T / E / N / R / S |
Is It Customised | Customisation |
Silicone Rubber Insulation provides superior flexibility, excellent softness, resistant to moisture and can be immersed in water for a longer period of time without much effect on its electrical & mechanical properties. Wide operating temperature range from -55 °C to 180 °C
APPLICATIONS |
· Medical Equipments |
· Food Equipments |
· Pharmaceuticals |
· Laboratories |
· Thermocouple Circuits |
· General Industry |
PRODUCT FEATURES |
· Continuous use up to 180 °C |
· Single Exposure up to 260 °C |
· Excellent Flexibility |
· Excellent softness |
· Resistant to moisture |
· Resistant to oil, solvent & chemicals |
Additional Information:
Product Details:
Product Type | CERAMIC YARN INSULATED THERMOCOPLE WIRE |
Brand | ELTEC |
Thermocouple Type | K, N & E |
Insulation Material | CERAMIC YARN |
Temperature | Up to 1000 C |
Length | 100 Mtrs. / 500 Mtrs. / 1000 Mtrs. / 2000 Mtrs. |
Accuracy | Class 1 |
Number Of Core | 2 |
Thermocouple Grade Wire | THERMOCOUPLE ORIGINAL GRADE |
Usage/Application | Used as a temperature sensor to measure temperature in furnace |
Limit Of Error | +-1.1 or 0.4% whichever is greater |
Outer Jacket | CERAMIC FIBER |
Referred Standards | ANSI MC 96.1 & ASTM E 230 |
Outer Braiding | SS WIRE optional |
Size | 20 AWG to 12 AWG solid wire |
Temperature Withstanding Capacity | 1000 C |
CERAMIC YARN INSULATION is ideal for HIGH TEMPERATURE APPLICATION.
PRODUCT FEATURES
· Continuous use up to 800 °C |
· Single exposure up to 1100 °C |
· Good Thermal Durability & Strength |
· Flame Retardant |
· Superior Abrasion Resistance |
· Better flexibility |
APPLICATIONS |
· Metal Production |
· Furnaces & Ovens |
· Braided Thermocouple Replacement |
· Heat Treatment |
· Brick And Tile kiln |
· Steel & Aluminum |
Additional Information:
Product Details:
Minimum Order Quantity | 1000 Meter |
Conductor Type | Thermocouple Original, Extension & Compensating Grade |
Size | 12 AWG to 24 AWG in solid & multi strand |
Thermocouple Type | J, K, T, E, N, R, S, B |
Brand | ELTEC |
Material | FEP |
Type of Thermocouple Calibration | J, K, T, E, N, R, S, B |
Temperature Withstanding Capacity | -200 C to 200 C |
Cable for Type of THERMOCOUPLE GRADE CALIBRATION: T, J, K, E, N, R, S, B
Thermal Accuracy conforms to AMERICAN Limits of Error ASTM E 230 & ANSI MC 96.1 IEC Thermal Tolerance Class EN 60584 -2
Application :
Features :
Additional Information:
Product Details:
Minimum Order Quantity | 300 Meter |
Size | 12 AWG to 24 AWG in solid & multi strand |
Thermocouple Type | All type of Therrocouple - J, K, T, E, N, R, S |
Usage/Application | Use as an extension purpose from thermocouple unit to control panel |
Number Of Core | 1 Pair, 2 Pair or even more as per customer requirement |
Brand | Eltec |
Material | PFA |
Temp. Withstanding Capacity | -65 to 260 C |
Type of Thermocopule Calibration | J,K,T,E,N,R,S |
Cable for Type of THERMOCOUPLE GRADE CALIBRATION: T, J, K, E, N, R, S, B
Thermal Accuracy conforms to AMERICAN Limits of Error ASTM E 230 – ANSI MC 96.1 IEC Thermal Tolerance Class EN 60584 – 2
Application :
Features :
Specification :
TYPE OF TC | Metal Alloy + ve leg | Metal Alloy – ve leg | Thermal Tolerance |
J | Fe | Cu Ni | ASTM E 230 – ANSI MC 96.1 IEC EN 60584 - 2 |
K | Ni Cr | Ni Al | ASTM E 230 – ANSI MC 96.1 IEC EN 60584-2 |
T | Cu | Cu Ni | ASTM E 230 – ANSI MC 96.1 IEC EN 60584- 2 |
E | Ni Cr | Cu Ni | ASTM E 230 – ANSI MC 96.1 IEC EN 60584 - 2 |
N | Ni Cr Si | Ni Si | ASTM E 230 – ANSI MC 96.1 IEC EN 60584 - 2 |
· Thermocouple wires are normally supplied to meet tolerance above 0 °C. If material is reqd. to meet tolerance below 0 °C, the purchaser should clearify the same in Purchase Order. Special selection of material is reqd.
· Initial calibration Tolerance suggested, its requirement should be discussed well in advance before placing the order.
Additional Information:
Product Details:
Minimum Order Quantity | 100 Meter |
Usage/Application | Use as an extension wire from thermocouple unit to control panel |
Power/Voltage | 600 V / 110 V |
Length | 100 Mtrs. / 200 Mtrs. / 500 Mtrs. |
Accuracy | As per ANSI MC 96.1 & IEC 60584 |
Brand | Eltec |
Material | PVC Insulation |
Type of Thermocoupole Calibration | J,K,T,E,N,R,S |
In an industrial environment of induced voltage and electrical noise, PVC Insulated twisted overall shielded thermocouple pairs is an ideal selection. Twisted pairs aluminum mylar shield provides protection against cross talk, static magnetic noise in thermocouple circuits.
Cable for Type of THERMOCOUPLE GRADE CALIBRATION: T, J, K, E, N, R, S, B
Thermal Accuracy conforms to AMERICAN Limits of Error ASTM E 230 – ANSI MC 96.1 IEC Thermal Tolerance Class EN 60584 – 2
Application :
Features :
Specification :
TYPE OF TC | Metal Alloy + ve leg | Metal Alloy – ve leg | Thermal Tolerance |
J | Fe | Cu Ni | ASTM E 230 – ANSI MC 96.1 IEC EN 60584 - 2 |
K | Ni Cr | Ni Al | ASTM E 230 – ANSI MC 96.1 IEC EN 60584-2 |
T | Cu | Cu Ni | ASTM E 230 – ANSI MC 96.1 IEC EN 60584- 2 |
E | Ni Cr | Cu Ni | ASTM E 230 – ANSI MC 96.1 IEC EN 60584 - 2 |
N | Ni Cr Si | Ni Si | ASTM E 230 – ANSI MC 96.1 IEC EN 60584 - 2 |
· Thermocouple wires are normally supplied to meet tolerance above 0 °C. If material is reqd. to meet tolerance below 0 °C, the purchaser should clearify the same in Purchase Order. Special selection of material is reqd.
Additional Information:
Product Details:
Minimum Order Quantity | 1000 Meter |
Conductor Type | Thermocouple Extension & Compensating Grade |
Size | 12 AWG to 24 AWG in solid & multi strand |
Material | PVC |
Color | As per ANSI MC 96.1, IEC 60584-3 and other International color code on request |
Brand | ELTEC |
Thermocouple Type | J, K, T, E, N, R, S, B |
Temperature | Standard |
Power/Voltage | 300 V |
Accuracy | As per ASTEM E 230 & ANSI MC 96.1 & IEC 60584-2 |
Number Of Core | 2 or more |
Usage/Application | Use as an extension wire from thermocouple to control unit |
Limit Of Error | As per ASTEM E 230 & ANSI MC 96.1 & IEC 60584-2 |
Operating Temp | 0 to 90 C |
Outer Jacket | PVC |
Referred Standards | As per ASTEM E 230 & ANSI MC 96.1 |
Country of Origin | Made in India |
PVC Insulation is one of the most common economical construction of THERMOCOUPLE wire with good moisture, chemical solvent resistance.
Good Flame retardancy, excellent die electric strength and continues use up to 105 °C. Poly Vinyl Chloride is extruded on thermocouple conductors and pairs laid parallel for outer extrusion of PVC JACKET.
THERMOCOUPLE EXTENSION GRADE: T, J, K, E, N,
THERMOCOUPLE COMPENSATING GRADE: T, K, E, N, R, S, B
Application :
Features :
Additional Information:
Product Details:
Minimum Order Quantity | 25 Meter |
Brand | Standard |
Insulating Material | Mineral Insulated |
Color | SS finish |
Number Of Cores | 2, 4 , 6 |
Wire Type | Standard |
Conductor Material | J, K, T, E, N, RTD PT 100 |
Usage/Application | Used to manufacture Thermocouple & RTD Sensors |
Additional Information:
Product Details:
Conductor Type | Thermocouple Original, Extension & Compensating Grade |
Brand | ELTEC |
Size | 12 AWG to 24 AWG in solid & multi strand |
Thermocouple Type | J, K, T, E, N, R, S, B |
Usage/Application | Use to build a thermocouple sensor or can be used as an Extension wire from control unit |
Cable Conductor | Thermocouple Original, Extension & Compensating Grade |
Number Of Cores | 2 core / 4 or multicore |
Jacket Type | PTFE |
Shape | Parallel or Twisted |
Packing Type | COIL or spool |
Material | PTFE Insulated |
PTFE Insulation becomes an excellent solution where chemical fumes & other liquids make all type of Insulation vulnerable as it is chemically inert to most of industrial chemicals. It has outstanding mechanical & electrical properties and has temperature range from -65 °C to 260 °C. It is flame retardant and none propagating in fire conditions.
ELTEC PTFE Insulated Thermocouple Wires conforms to US Military MIL – W – 16878 and Indian defense specifications JSS 51034.
PRODUCT FEATURES |
· Continuous use up to 260 °C |
· Single exposure up to 400 °C |
· Inert to most chemical & fluids |
· Unaffected by lubricants |
· Flame Retardant |
· Immune to agene fungus & water absorption |
· Resistant to gamma radiation |
APPLICATIONS |
· Manufacturing of Temperature Sensors |
· Furnaces & Ovens |
· Plastic Processing Equipments |
· Heat Treatment |
· Thermocouple Circuits |
· Various Processing Industries |
|
Additional Information: